The customer needs a size. Nobody is standing there.
Occupancy sensors and a screen in the fitting room let a customer request another size without getting dressed again — and route that request straight to the nearest associate's phone.
How it works, briefly: an occupancy sensor registers the room as in use, the in-room screen offers the sizes and colours the customer can request, a tap creates a task, the dispatch engine assigns it to the nearest available associate by zone, and their handheld shows the room number, the item and the size. Tap to associate notification typically takes under four seconds.
The alternative is what happens now: the customer gets dressed, finds the floor empty, and leaves without buying.
How fitting room automation works, in five steps
From the customer's tap to the associate accepting the task. Timings are measured on a normal store network; each step is instrumented, so you can see where a slow store is actually slow.
The sensor registers occupancy < 1 s
A presence sensor mounted above the door registers the room as occupied and wakes the in-room screen. Until this fires, the screen shows nothing — no idle attract loop, no interface for an empty room.
room.occupied with room ID and timestampThe screen shows what's in the room 1–2 s
Where garments are RFID tagged, the reader identifies what the customer carried in and the screen lists those items with their available sizes and colourways — live stock for this store, not a generic size run.
Without RFID, the customer scans or searches the item instead. It works, but it adds friction at the exact moment you're trying to remove it.
The customer taps a size instant
One tap creates a task. The screen immediately confirms the request has gone and shows its state, so the customer isn't left wondering whether anything happened — the single biggest cause of people giving up and getting dressed.
task.created — room, item, size, requested-atDispatch picks an associate < 1 s
The engine ranks available associates and assigns the task to one — not to everybody. Broadcasting to the whole floor is how these systems fail: five people walk over, or nobody does because each assumes someone else has it.
The associate accepts and delivers tap → notify: ~3.4 s total
Their handheld shows the room number, the item, the size and where that size is on the floor. They accept, collect it, and mark it delivered — which closes the task and updates the customer's screen.
If nobody accepts within 45 seconds the task escalates: first to the zone lead, then to the whole floor, then to the manager's device with the wait time attached.
task.delivered, which stops the clock and logs the full response timeEvery step is timestamped. Which means "service is slow in womenswear on Saturdays" stops being a complaint and becomes a measurement you can act on — and you can see whether the delay is in accepting the task or in walking it over.
How "nearest associate" is actually decided
Nearest is not a GPS position. Indoor positioning accurate enough to rank people a few metres apart is expensive, fragile, and more surveillance than most staff will accept. Zones are better.
// Candidate ranking, simplified score = (zoneDistance(associate.zone, stockLocation) * 3.0) + (openTasks(associate) * 2.0) - (minutesSinceLastTask(associate) * 0.2) // excluded entirely associate.status in ["break", "till", "offline"] openTasks(associate) >= 2 // lowest score wins; 45s to accept, then escalate
Zones, not coordinates
The floor is divided into zones at setup. Associates select their zone at shift start, or it's set by the rota. Adjacency is a simple map — no beacons, no indoor positioning, no tracking anyone's movement.
Load balancing built in
The minutesSinceLastTask term stops the same reliable person absorbing every request. Without it, your best associate quietly becomes the fitting room runner and resents it.
Tuned per store
A small boutique may want proximity weighted heavily; a two-floor department store needs load balancing to dominate. The weights are configuration, not code.
What goes into a fitting room
Four components per room, one controller per bank of rooms. Non-invasive install — no construction, no new circuits.
Presence sensor
Detects occupancy without imaging. Mounted in the door frame or ceiling. This is what wakes the room and starts the dwell timer.
In-room screen
A small touch display, typically 10 to 15 inches, mounted beside the mirror. Dark until the room is occupied.
RFID reader
Identifies tagged garments carried in. Optional, but it's the difference between a one-tap request and the customer typing in a product name.
Room controller
One unit serves a bank of rooms. Handles sensor input, drives the screens and talks outbound to the dispatch service. No inbound firewall rule.
RFID is the real prerequisite for step 2. If your garments aren't tagged at source, that's the project to scope before anything else — it's where the cost and the timeline sit. Steps 1, 3, 4 and 5 all work without it; only the automatic item identification needs it.
What occupancy data gives you beyond dispatch
How many rooms are free, shown on a floor screen or to the greeter. Stops the "is anyone in there?" door knock and the awkward queue down the aisle.
A room occupied far longer than normal with no request logged usually means someone is waiting, stuck or struggling. Flag it to an associate rather than discovering it later.
Rooms flagged by actual use rather than a fixed hourly round. Reclaims staff time and keeps the heavily used rooms genuinely clean.
Occupancy against purchases traced back to that session. Consistently poor rooms usually have a lighting or mirror problem you can fix cheaply.
Peak occupancy by day and hour, against how long requests waited. This is the argument for the extra Saturday shift, with numbers behind it.
Every request logs the size asked for, including sizes you didn't have. Straight into the merchandising report.
What happens when something fails
A fitting room request that silently disappears is worse than no system at all — the customer waited, trusted it, and then left. Every path below ends somewhere.
| Situation | What the system does | What the customer sees |
|---|---|---|
| Nobody accepts in 45 s | Escalate to the zone lead, then the floor, then the manager | Status still live; no silence |
| Associate accepts, then doesn't deliver | Reassign after 3 minutes, flagged on the manager dashboard | Reassigned, clock keeps running |
| Size isn't actually on the floor | Close honestly as unavailable | Told it's unavailable, offered order-to-home |
| Screen offline | Alert raised; room drops out of the pool | Dark screen — same as a room without one |
| Store network down | Controller buffers and replays on reconnect | Request queued, state shown honestly |
| No associates on shift in zone | Widen to all zones immediately, no 45 s wait | Normal flow, slightly longer |
The hard rule: the customer is never told a size is coming when it isn't. An honest "we don't have that in store, want it sent to you?" converts better than a promise nobody keeps.
How a rollout actually goes
- One bank of rooms first. Four to six rooms in your busiest department. Enough volume to learn from, small enough to change your mind about.
- Zones and weights are configured on site, with the store manager, not from head office. They know where stock actually lives.
- Associate training is about ten minutes. Accept, collect, mark delivered. If it needs more than that, the interface is wrong.
- Two weeks shadow running before you publicise it to customers — enough to catch the zone map being wrong and the escalation window being too short.
- Expect to retune the 45-second window. Small stores often want 30; a large floor sometimes needs 60. It's the setting that changes most often after go-live.
Honest timeline: a single bank of rooms installs in a day. Getting the zone map and weights right takes a fortnight of real trading.
Sensors in fitting rooms and privacy
This is the most sensitive space in a store. The position below isn't negotiable on our side.
- No cameras in fitting rooms. Ever. Occupancy is detected by presence sensors that produce a boolean, not an image. There is no imaging device in the room.
- No audio. No microphone in the room, in the controller, or in the screen.
- Garments, not people. RFID identifies tagged stock. It says a size-M overshirt is in room 3 — it says nothing about who is wearing it.
- No identification of the customer. A request is tied to a room and a session, not to a person, unless they deliberately signed in to your loyalty app themselves.
- Session data expires. What persists is the aggregate — wait times, size requests, occupancy patterns — not individual sessions.
- Associate location is zone-level and self-declared. We don't track staff movement around the floor, and we'd push back if asked to.
Worth stating plainly to staff as well as customers: several of these choices exist because continuous location tracking of retail workers is both a labour-relations problem and, in some jurisdictions, a regulated one. Your legal and HR teams should confirm the configuration fits your obligations.
Frequently asked questions
How does fitting room automation work?
In five steps. A presence sensor detects the room is occupied and wakes the screen. An RFID reader identifies the garments carried in and the screen shows available sizes. The customer taps a size, creating a task. A dispatch engine assigns that task to one nearby available associate rather than broadcasting it. The associate's handheld shows the room, item, size and stock location, and they accept and deliver it.
From tap to associate notification typically takes under four seconds. If nobody accepts within 45 seconds the request escalates to a zone lead, then the whole floor.
How is the nearest associate determined?
By zone, not by GPS. The sales floor is divided into zones at setup and associates select their zone at shift start. The dispatch engine ranks candidates on zone proximity to the stock location, current open task count, and time since their last task, excluding anyone on break, at the till or already holding two tasks. Indoor positioning accurate enough to rank people metres apart is expensive, unreliable, and more staff surveillance than most retailers want.
Are there cameras in the fitting rooms?
No. Occupancy is detected by presence sensors that output occupied or not occupied — there is no imaging device and no microphone in the room. Garment identification comes from RFID tags on the stock, which identifies the item, not the person.
What if no associate responds?
The task escalates. After 45 seconds it goes to the zone lead, then to the whole floor, then to the manager's device with the customer's wait time attached. If an associate accepts but doesn't deliver within three minutes it is reassigned and flagged. The customer's screen shows live status throughout — a request never silently disappears.
Do we need RFID tagging?
Only for automatic item identification in step 2. Without it, the customer scans or searches the item instead, which works but adds friction. Occupancy detection, the request flow, dispatch and delivery all function without any tagging.
What does it do when the network drops?
The room controller buffers requests locally and replays them when connectivity returns. The screen shows the request as queued rather than claiming it's been dispatched. Controllers connect outbound only, so no inbound firewall rule or VPN into the store is required.
How long does a deployment take?
A single bank of four to six rooms installs in a day. Getting the zone map, dispatch weights and escalation window right takes about two weeks of real trading — we'd recommend shadow running for that fortnight before telling customers the feature exists.
Start with one bank of rooms.
Tell us how your floor is laid out and how many associates work it. We'll map the zones, size the hardware and tell you what the fortnight of tuning involves.